TSARA Plus
Designed for the control of insecticide resistant mosquito populations. Contains primary insecticide Deltamethrin and co-insecticide PBO that suppress the mosquito’s enzyme defenses which considerably enhances the effectiveness.
Trade name | TSARA Plus | |
Common name | Deltamethrin Long Lasting (coated onto filaments) Insecticidal net combined with Deltamethrin+Piperonyl butoxide Long Lasting (incorporated into filaments) Insecticidal net |
WHO specification 333+33/LN/2 (NETTING) (2019) and WHO specification 333/LN/2 (2019) |
---|---|---|
PQ VC Ref | P-00226 | |
Specification | Requirements | Test standards |
Active ingredient identity | Deltamethrin | Roof: 333/LN/(M2)/2, CIPAC Handbook N, p.34, 2012 Sides: 333/LN/(M)/2, CIPAC Handbook M, p.66, 2009 |
Deltamethrin content | Roof: 3 g/kg ±25% (120 mg/m² ±25%) Sides: 2.5 g/kg ±25% (100 mg/m² ±25%) |
Roof: 333/LN/(M2)/3, CIPAC Handbook N, p.34, 2012 Sides: 333/LN/(M)/3, CIPAC Handbook M, p.66, 2009 |
Co-insecticide identity | Piperonyl butoxide (PBO) | 33/LN/(M)/2, CIPAC Handbook N, p.111, 2012 |
Piperonyl butoxide content | Roof: 11 g/kg ±25% (440 mg/m² ±25%) | 33/LN/(M)/3, CIPAC Handbook N, p.111, 2012 |
Wash resistance | 20 washes | WHOPES/GCDPP/2005.11 |
Wash retention index Deltamethrin |
Sides: 0.90 – 1.00 Roof: 0.93 – 1.00 |
Roof: MT 195, CIPAC Handbook O, p.205, 2017 Sides:MT 195, CIPAC Handbook O, p.205, 2017 |
Wash retention index PBO | 0.90 – 1.00 | MT 195, CIPAC Handbook O, p.205, 2017 |
Storage stability | 54°C ±2°C for 14 days <5% loss of deltamethrin (PBO) |
MT 46.3.4, CIPAC Handbook O, p.176, 2017 |
Material | Roof: 100% polyethylene, mono-filament Sides: 100% polyester, multi-filament |
ISO 1833 |
Fabrication | Warp knitted | ISO 8388 |
Denier | Roof: 130 ±5%; Sides: 100 ±5% | ISO 2060 |
Mesh | Roof: 17 holes/cm² (not less than 16) Sides: 24 holes/cm² (not less than 23) |
CITEVE 110 |
Dimensional stability | Maximum 5% shrinkage Maximum 5% expansion |
Method of preparation, marking and measuring: ISO 3759 Method of washing: ISO 6330 Method of calculation: ISO 5077 |
Bursting strength | Roof: Minimum 400 kPa Side: Minimum 350 kPa |
ISO 13938:2 |
Seam Strength | Greater or equal to Fabric Bursting Strength | |
Weight | 40 g/m² ±10% | ISO 3801 / EN 12127 |
Fire safety | Non-ignitable (NI) | EN 1102 |